Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.837
Filtrar
1.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730391

RESUMO

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Titânio , Titânio/química , Humanos , Porcelana Dentária/química , Polietilenoglicóis/química , Materiais Dentários/química , Polímeros , Cetonas/química , Zircônio/química , Implantes Dentários para Um Único Dente , Teste de Materiais , Projeto do Implante Dentário-Pivô , Fenômenos Biomecânicos
2.
J Contemp Dent Pract ; 25(3): 213-220, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690692

RESUMO

AIM: The objective of this study was to assess marginal bone level around single implants inserted in fresh extraction sockets in the anterior maxillary region and instantly restored with computer-aided design/computer-aided manufacturing customized temporary crowns cemented on the final abutment. MATERIALS AND METHODS: A total of 20 patients (15 females and 5 males, with a mean age of 30 years), where 20 were placed in fresh extraction sockets. After raising a full-thickness flap, atraumatic extraction was performed the implant site was prepared and fixtures were stabilized on the palatal bone wall. The implant location was immediately transmitted to the prepared master model using the pick-up impression coping seated in the surgical guide template. Prefabricated abutments were used as the final abutment on the master model, scanned and the crown was planned using computer-aided manufacturing customized software. Later on 8th weeks, abutments were torqued as per the manufacturer's recommendation, and the final crowns were cemented. Using personalized intraoral radiographs marginal bone level was evaluated mesially and distally to the implant shoulder as a reference at implant placement, 8 weeks, 1, 3, 5, and 10 years after loading. RESULTS: Wholly implants were osteo-integrated positively after 10 years of practical loading, but only 18 were available for clinical and radiological follow-up, and 2 patients with two implants were excluded from the study due to relocation abroad without any implant failure. The average marginal bone loss (MBL) in the current report was 0.16 ± 0.167 mm at crown cementation, 0.275 ± 0.171 mm after 1 year, 0.265 ± 0.171 mm after 3 years, 0.213 ± 0.185 mm after 5 years, and 0.217 ± 0.194 mm at 10 years. CONCLUSION: The strategy of inserting and not removing the final abutment at the time of implant placement facilitates the establishment of adequate attachment of both soft and hard tissues to the abutment surface, ensuring uninterrupted organization of tissue architecture and offers advantages in helping maintain soft tissue maturation and preventing marginal bone level. CLINICAL SIGNIFICANCE: Immediately loaded implants in freshly extracted sockets lead to a significant reduction in marginal ridge resorption. The use of a temporary crown on a prefabricated abutment, exclusive of successive abutment manipulation, proved effective in preserving the primarily founding blood clot and served as a prototype for shaping the soft tissue around the previously wounded gum. How to cite this article: Berberi A, El Zoghbi A, Aad G, et al. Immediate Loading Using the Digitalized Customized Restoration of Single-tooth Implants Placed in Fresh Extraction Sockets in the Aesthetic Anterior Maxilla: A 10-Year Prospective Study of Marginal Bone Level. J Contemp Dent Pract 2024;25(3):213-220.


Assuntos
Desenho Assistido por Computador , Coroas , Implantes Dentários para Um Único Dente , Carga Imediata em Implante Dentário , Maxila , Alvéolo Dental , Humanos , Masculino , Feminino , Estudos Prospectivos , Maxila/cirurgia , Adulto , Carga Imediata em Implante Dentário/métodos , Alvéolo Dental/cirurgia , Perda do Osso Alveolar , Dente Suporte , Estética Dentária , Extração Dentária , Prótese Dentária Fixada por Implante , Planejamento de Prótese Dentária , Projeto do Implante Dentário-Pivô , Adulto Jovem
3.
J Dent ; 144: 104987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580056

RESUMO

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Teste de Materiais , Porcelana Dentária/química , Humanos , Dente Suporte , Cerâmica/química , Propriedades de Superfície , Materiais Dentários/química , Adaptação Marginal Dentária , Ligas de Cromo/química
4.
Int J Oral Maxillofac Implants ; 39(2): 235-242, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657216

RESUMO

PURPOSE: To analyze the effectiveness of coating of abutments with antimicrobial agents and their influence on the physicochemical and biologic properties of the coated materials. MATERIALS AND METHODS: This work was registered in Open Science Framework (osf.io/6tkcp) and followed the PRISMA protocols. A search of two independent reviewers of articles published up to October 29, 2021, was performed in the Embase, PubMed, Science Direct, and Scopus databases. RESULTS: The databases found a total of 1,474 references. After excluding the duplicates, 1,050 remained. After reading the titles and abstracts and applying the inclusion criteria, 13 articles remained and were read in full. A total of 8 articles were included in this systematic review. Different antimicrobial agents have been used to coat abutments, including graphene oxide, polydopamine, titanium and zirconium nitride, lactoferrin, tetracycline, silver, and doxycycline with varied release times. Titanium-coated silver showed a better antimicrobial agent release time of up to 28 days. Chemical analysis confirmed the presence of antimicrobials on the surface after coating. Different pathogenic microorganisms, such as Streptococcus sanguinis, Streptococcus oralis, and Staphylococcus aureus, were inhibited when in contact with the coated surface. CONCLUSIONS: This review showed that there is still no consensus on which is the better antimicrobial agent and which coated materials have the better performance. However, the association of surface coating of abutments with antimicrobials is feasible and can benefit many patients, which can support their clinical use to favor the healing process and prevent infections that can lead to treatment failure with dental implants.


Assuntos
Anti-Infecciosos , Dente Suporte , Humanos , Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Dente Suporte/microbiologia , Propriedades de Superfície , Titânio/química
5.
J Oral Implantol ; 50(1): 45-49, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579112

RESUMO

The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.


Assuntos
Implantes Dentários , Carbono , Titânio , Análise do Estresse Dentário/métodos , Torque , Parafusos Ósseos , Dente Suporte
6.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579114

RESUMO

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Assuntos
Implantes Dentários , Torque , Dente Suporte , Análise do Estresse Dentário , Retenção em Prótese Dentária , Projeto do Implante Dentário-Pivô
7.
Int J Oral Maxillofac Implants ; 39(2): 278-285, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38657220

RESUMO

PURPOSE: To evaluate and compare the difference in retention between implant-supported restorations with and without surface modification of the implant abutments. MATERIALS AND METHODS: A total of 30 patients with singletooth implants were restored with cement-retained (Multilink N, Ivoclar) restorations using titanium base abutments (Variobase, Straumann) and randomly assigned surface modifications. Group 1 used nonmodified abutments, group 2 used sandblasted abutments, and group 3 used sandblasted abutments followed by an application of metal primer. All patients were recalled for a baseline examination 6 months after crown placement. The pull-out strength and intergroup distribution of mean pull-out strength were assessed. To assess differences between the three groups, intergroup statistical comparison of continuous variables was done using one-way ANOVA with Tukey correction for multiple group comparisons. RESULTS: The results of the intergroup mean pull-out strength distribution revealed that the distribution of mean ± SD pull-out strength in group 1, group 2, and group 3 were 220.79 ± 94.23, 488.64 ± 84.12, and 705.46 ± 112.75 Ncm, respectively. CONCLUSIONS: Sandblasting followed by the application of metal primer produced the highest retention of porcelain-fused-to-metal (PFM) crowns to titanium base abutments, followed by sandblasting alone, with the least retention being observed with no surface treatment.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Metacrilatos , Propriedades de Superfície , Titânio , Humanos , Feminino , Masculino , Titânio/química , Pessoa de Meia-Idade , Coroas , Adulto , Análise do Estresse Dentário
8.
J Prosthet Dent ; 131(5): 933.e1-933.e7, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429151

RESUMO

STATEMENT OF PROBLEM: The connector height and retainer occlusal thickness of fixed partial dentures (FPDs) may affect restoration longevity. PURPOSE: The purpose of this in vitro study was to determine and compare the fracture resistance of 4-unit monolithic 5% yttria tetragonal zirconia polycrystal (5Y-TZP) FPDs made with different connector heights and retainer occlusal thicknesses after thermomechanical aging. MATERIAL AND METHODS: Forty test metal dies were duplicated from a master metal die containing 2 anatomic abutment preparations of the mandibular right first premolar and second molar for a 4-unit FPD. The dies were divided into 2 groups of 20 each for the fabrication of 4-unit FPDs, with 2-mm and 4-mm uniform connector heights at all 3 connectors, resulting in 6.3-mm2 and 12.6-mm2 connector areas. Each of these groups was further divided into 2 subgroups based on the occlusal thickness of the 2 retainers of 1 mm and 2 mm (n=10). Polyvinyl siloxane impressions of the test metal dies were made and poured in Type V dental stone. Laboratory scans were performed on all the stone dies, and 40 5Y-TZP FPDs (Ceramill Zolid FX) were designed and fabricated. Subsequently, all the FPDs were luted on to the metal dies with a self-adhesive resin cement. The FPDs were preloaded (400 000 mechanical cycles; 4000 thermocycles) using a mastication simulator and tested for axial compressive strength. Two-way analysis of variance (ANOVA) was used to examine the effect of connector and occlusal thicknesses on the fracture load (α=.05). The data were further assessed using the post hoc Tukey HSD multiple comparison test (α=.05). RESULTS: The mean fracture load values were between 737 N and 1563 N. Significant differences in the mean fracture load were found between the connector heights (601 N; P<.001) and occlusal thicknesses (225 N; P=.002), but the interaction of the 2 factors was not significant (P=.132) The Tukey post hoc analysis showed significant differences between the connector thicknesses groups (P<.01), but the occlusal thicknesses were found to be similar for the same connector height (P=.609) CONCLUSIONS: Connector height and occlusal retainer thickness influenced the fracture load of 4-unit monolithic 5Y-TZP FPDs after thermomechanical aging.


Assuntos
Análise do Estresse Dentário , Planejamento de Dentadura , Prótese Parcial Fixa , Ítrio , Zircônio , Zircônio/química , Ítrio/química , Falha de Restauração Dentária , Humanos , Teste de Materiais , Técnicas In Vitro , Materiais Dentários/química , Dente Suporte
11.
J Dent ; 144: 104943, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38494043

RESUMO

OBJECTIVES: This study aimed to evaluate the accuracy of an intraoral scanner (IOS - Medit i700) on tooth abutments with vertical preparations at 2 depths below the free gingival margin, and to determine if the IOS can reproduce the area beyond the finish surface of the tested preparation geometry. METHODS: Two abutments for a maxillary first molar were designed by means of CAD software, with vertical preparations set at 1 and 2 mm below the gingiva. These abutments were subsequently printed in resin and placed on a reference model. The reference files consisted of scans made using a metrological machine on these abutments. Ten scans were made with the tested IOS on each sample, resulting in two study groups. The scans from the experimental groups were labeled "V-1″ for vertical preparation at 1 mm below the gingival margin and "V-2″ for 2 mm below. The analysis of these scans was performed using Geomagic Control X (3D SYSTEMS) to assess their trueness and precision in µm. Descriptive statistics with a 95 % confidence interval were employed, alongside independent sample tests, to ascertain any differences between the groups (α=0.05). RESULTS: Statistically significant differences were not found both for trueness (p=.104) and precision (p=.409), between the tested geometries. The mean values for trueness were V-1 = 37.5[31.4-43.6]; V-2 = 32.6[30.6-34.6]. About the precision, the mean values were V-1 = 20.5[8.4-32.5]; V-2 = 18.4[8.2-28.5]. In both the study groups, it was possible to detect the surface beyond the finish area. CONCLUSIONS: Within the limitations of this study, vertical preparation design allows for registration of the tooth anatomy beyond the finish area with IOS. Moreover, the mean accuracy values were clinically acceptable at both 1 and 2 mm below the gingival margin.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Gengiva , Humanos , Gengiva/diagnóstico por imagem , Gengiva/anatomia & histologia , Dente Molar/diagnóstico por imagem , Técnicas In Vitro , Planejamento de Prótese Dentária/métodos , Reprodutibilidade dos Testes , Software , Imageamento Tridimensional/métodos
12.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532413

RESUMO

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Assuntos
Coroas , Cimentos Dentários , Zircônio , Humanos , Torque , Teste de Materiais , Dente Suporte , Titânio , Parafusos Ósseos , Análise do Estresse Dentário , Falha de Restauração Dentária
13.
BMC Oral Health ; 24(1): 396, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549137

RESUMO

BACKGROUND: The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. METHODS: Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N - 90º, 100 N - 90º, 200 N - 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 µm. RESULTS: Microgaps were present in all implant systems prior to loading (0.15-9 µm). Values increased with mounting force and angle up to 40.5 µm at an off axis loading of 100 N in a 90° angle. CONCLUSIONS: In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.


Assuntos
Implantes Dentários , Síncrotrons , Humanos , Projeto do Implante Dentário-Pivô , Simulação por Computador , Dente Suporte , Análise do Estresse Dentário
14.
Int J Implant Dent ; 10(1): 13, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38498247

RESUMO

PURPOSE: Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). METHODS: This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. RESULTS: ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. CONCLUSION: ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone.


Assuntos
Qualidade de Vida , Titânio , Humanos , Estudos Transversais , Titânio/química , Estética Dentária , Zircônio/química , Dente Suporte
16.
Int J Prosthodont ; 37(1): 16-26, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381982

RESUMO

PURPOSE: To examine the influence of abutment emergence angle and abutment height on marginal peri-implant bone stability in patients not considered susceptible to peri-implantitis. Furthermore, it was analyzed whether titanium-base (Ti-base) abutments lead to wider abutment emergence angles compared to one-piece abutments. MATERIALS AND METHODS: A total of 48 abutments (ie, 24 Ti-base and 24 one-piece abutments in 24 patients) were evaluated at abutment installation, after 1 year, and thereafter on a yearly basis for up to 5 years. Clinical and radiographic outcome variables were assessed. RESULTS: With regard to peri-implant marginal bone stability, only moderately negative, albeit significant, correlations were found on the mesial sides of the one-piece abutments after 4 and 5 years for an abutment emergence angle > 30 degrees. No statistically significant negative correlations were found for distances of ≤ 1.5 mm between the restoration margin and the crestal peri-implant bone level for either Ti-base or for one-piece abutments. Furthermore, abutments bonded to Ti-bases were not associated with larger emergence angles than one-piece abutments. CONCLUSIONS: For patients at low risk of developing peri-implantitis, it can be concluded that neither a larger abutment emergence angle (> 30 degrees) nor a distance of ≤ 1.5 mm between the restoration margin and the crestal peri-implant bone level are associated with marginal peri-implant bone loss. Furthermore, abutments bonded to Ti-bases are not associated with wider emergence angles than one-piece abutments.


Assuntos
Implantes Dentários , Peri-Implantite , Humanos , Dente Suporte , Peri-Implantite/etiologia , Estudos Retrospectivos , Titânio , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Int J Prosthodont ; 37(1): 109, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381989

RESUMO

PURPOSE: To determine and compare the frequency of contamination on different sites of healing abutments (HAs) after sterilization with Phloxine B dye on unused and used HAs after sterilization. MATERIALS AND METHODS: A total of 60 HAs were divided into two test groups: (1) used and sterilized and (2) a control group (unused). The test group was evaluated for contamination after sterilization; the control group did not undergo any procedure. Data were analyzed using SPSS version 22 (IBM). Descriptive statistics were used to determine the frequency of contamination in the different groups and at the different HA sites. Chi-square test was used to evaluate the association of frequency of contamination with the HA site and design. The level of significance was kept at P ≤ .01. RESULTS: The test group showed more contamination compared to the control group. The most contaminated sites were the screw thread and the screwdriver engagement location. CONCLUSIONS: HA reuse is cost-effective, but cleaning and sterilization was not effective for these components; thus, HAs need to be reused with caution because they were heavily contaminated when compared to new HAs. Among the different sites, the screw thread and screwdriver engagement sites were more prone to contamination. HA type did not influence the frequency of contamination.


Assuntos
Dente Suporte , Implantes Dentários , Propriedades de Superfície , Reutilização de Equipamento , Esterilização/métodos , Contaminação de Equipamentos
18.
Int J Prosthodont ; 37(1): 59-71, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381985

RESUMO

PURPOSE: To evaluate the effectiveness and accuracy of a proposed duplication technique in terms of one- and three-dimensional discrepancies between an original abutment and polyurethane duplicates obtained through a conventional workflow in single-implant rehabilitation. MATERIALS AND METHODS: A titanium, shoulderless abutment was chosen for a single-implant cemented rehabilitation. The master cast was made using a plastic-based die system, and the implant portion was separated. The implant section was consecutively duplicated eight times using a manual technique with polyvinyl siloxane and unfilled polyurethane resin as impression and die materials. The duplicates were analyzed with a coordinate-measuring machine (SmartScope Flash 200, Optical Gaging Products): one- and three- dimensional discrepancies were determined for each duplicate on 20 analysis points (A to T) located on the abutment surface. Changes in the abutment radius were also calculated to estimate the effects on cement thicknesses. RESULTS: One-dimensional discrepancies were -0.5 Å} 61.2 µm, -6.6 Å} 39.7 µm, and -19.4 Å} 47.8 µm on the X, Y, and Z axes, respectively; three-dimensional variation was -66.4 Å} 60.1 µm. Friedman test showed no significant difference between duplicates' one-dimensional variations on X (P = .059), Y (P = .156), or Z (P = .223) axes; a significant difference was found regarding three-dimensional changes (P < .001). Dunn test showed higher discrepancies on the X axis and on the abutment head. Mean variation of the abutment radius was -12.09 µm. CONCLUSIONS: The abutment duplication technique was shown to be an accurate and repeatable procedure for single cementable restorations.


Assuntos
Implantes Dentários , Poliuretanos , Cimentos Dentários , Titânio , Dente Suporte
19.
ACS Appl Bio Mater ; 7(2): 936-949, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38299869

RESUMO

In this study, a recently reported Ti-based metallic glass (MG), without any toxic element, but with a significant amount of metalloid (Si-Ge-B, 18 atom %) and minor soft element (Sn, 2 atom %), was produced in ribbon form using conventional single-roller melt-spinning. The produced Ti60Zr20Si8Ge7B3Sn2 ribbons were investigated by differential scanning calorimetry and X-ray diffraction to confirm their amorphous structure, and their corrosion properties were further investigated by open-circuit potential and cyclic polarization tests. The ribbon's surface was functionalized by tannic acid, a natural plant-based polyphenol, to enhance its performance in terms of corrosion prevention and antimicrobial efficacy. These properties can potentially be exploited in the premucosal parts of dental implants (abutments). The Folin and Ciocalteu test was used for the quantification of tannic acid (TA) grafted on the ribbon surface and of its redox activity. Fluorescent microscopy and ζ-potential measurements were used to confirm the presence of TA on the surfaces of the ribbons. The cytocompatibility evaluation (indirect and direct) of TA-functionalized Ti60Zr20Si8Ge7B3Sn2 MG ribbons toward primary human gingival fibroblast demonstrated that no significant differences in cell viability were detected between the functionalized and as-produced (control) MG ribbons. Finally, the antibacterial investigation of TA-functionalized samples against Staphylococcus aureus demonstrated the specimens' antimicrobial properties, shown by scanning electron microscopy images after 24 h, presenting a few single colonies remaining on their surfaces. The thickness of bacterial aggregations (biofilm-like) that were formed on the surface of the as-produced samples reduced from 3.5 to 1.5 µm.


Assuntos
Dente Suporte , Polifenóis , Titânio , Humanos , Titânio/química , Vidro/química , Antibacterianos/farmacologia
20.
J Oral Implantol ; 50(2): 81-86, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38353278

RESUMO

Reports of implant fixtures dislocating into the maxillary sinus during sinus graft procedures are well-documented. However, cases of fixtures migrating into the sinus long after placement have yet to be reported. This case report details the surgical extraction of a displaced screw and cement-retained prosthesis, including a fixture and its abutment, from the maxillary sinus after a minimum of 5 years under functional load. The extracted implant was subsequently examined using scanning electron microscopy and energy-dispersive x-ray spectroscopy. We found that the migration commenced with peri-implantitis surrounding the implant, replacing the second molar. This was accompanied by a loss of cement from the crown on this implant and concurrent loosening of the abutment screw on the implant, replacing the first molar. We hypothesize that the inability of the bony tissue surrounding the second molar implant to withstand occlusal forces resulted in forming a bony sequestrum. This process ultimately precipitated the migration of the fixture, along with its abutment and adjacent necrotic bone, into the sinus cavity.


Assuntos
Migração de Corpo Estranho , Seio Maxilar , Humanos , Seio Maxilar/cirurgia , Migração de Corpo Estranho/cirurgia , Microscopia Eletrônica de Varredura , Peri-Implantite/etiologia , Peri-Implantite/cirurgia , Falha de Restauração Dentária , Implantes Dentários , Masculino , Pessoa de Meia-Idade , Remoção de Dispositivo , Dente Suporte , Feminino , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...